5.2 Columns

CL Columns (Framed Buildings)

The upright supports to upper floors and roof forming part of a framed structure.

It INCLUDES internal and external columns from tops of columns to bases; column casings; all protective non-decorative coatings.

It EXCLUDES portal frames (RF); columns to non-framed (load bearing) structures (EW, NW); columns supporting awnings and attached covered ways (RF); columns supporting exposed attached external stairs (SC); all finishes (EW, WF).

Note: Columns below lowest floor finish (eg. in filled areas) are included in this element because of the impracticability of splitting a column into two elements.

Verify Element Properties

This cost plan element is a straightforward extraction from the Revit default Structural Columns category. In this project, columns comprise cast in-situ concrete and structural steel columns.

The default unit of measurement for both cast in-situ concrete and structural steel columns is volume (m³).

ANZSMM Measurement Rules

The units of measurement for cast in-situ concrete and structural steel are volume (m³) and mass (t) respectively.

14. Structural Steel

To Take Note

Quantity Extraction

Use VG to isolate the structural columns on the canvas, Run the following QTO quantities:

  1. Structural Framing and Columns
  2. Formwork.

The line item Family: SC_Reference Column has no quantities attached. As it is not a structural steel element, add the QS Remark “Ref-nil” for future reference.

Your completed Columns element in the Workbook and Export BQ should look like this:

Workbook Summary
Workbook Columns
Export BQ Columns

Quality Assurance (QA) Checks

Summary

CategoryCost Plan ElementsQTO ScheduleLinked to Workbook /
Excluded
Structural ColumnsConcrete columns
Structural steel columns
14 lines13 lines linked +
1 line unlinked Ref-nil qty
(Excluded)